<LOGO>
FM Transmitter Measurement Report
Created: 2022-08-19 14-39-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 30 dBuV R-PCE
Pilot RDS Phase Difference
7.2 kHz 5.2 kHz 67 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
22 kHz 40 kHz 15492 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr -0,07 dBr 0,5 dBr 24,4
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 14:38, 19.08.2022
RT
"RANGERS - 500 MIL "
AF EON
98.6, 101.0, 102.4, 104.7 MHz -
FM Scope Max at: 40 kHz MIN: 22 kHz % above 77 kHz: 0,0000 Acquired: 2022/08/19 14:39:16 Total samples: 15492 Equivalent time: 0:12:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,5 dBr MIN: -1,0 dBr AVE: -0,07 dBr % above 0,2 dBr: 24,4 Last value: 0,1 dBr (2022/08/19 14:39:15) 14:26 14:28 14:30 14:32 14:34 14:36 14:38 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality