<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-18 05-39-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 4/5, 23 dBuV FAKTOR
Pilot RDS Phase Difference
6.9 kHz -19 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
18 kHz 36 kHz 3560 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -1,09 dBr -0,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" FAKTOR " 2550 10 (Pop M) 1 0 1 5 5:39, 18.03.2024
RT
"OFFSPRING - Why Don't You Get A Job "
AF EON
87.6, 88.0, 90.1, 93.6, 94.6, 98.3, 104.3 MHz -
FM Scope Max at: 36 kHz MIN: 18 kHz % above 77 kHz: 0,0000 Acquired: 2024/03/18 5:39:20 Total samples: 3560 Equivalent time: 0:02:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: -0,8 dBr MIN: -1,6 dBr AVE: -1,09 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/03/18 5:39:20) 05:26 05:28 05:30 05:32 05:34 05:36 05:38 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality