<LOGO>
FM Transmitter Measurement Report
Created: 2022-08-20 04-06-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 34 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 10 kHz 18552 0,0809
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-14,0 dBr -2,09 dBr 0,7 dBr 6,5
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 4:05, 20.08.2022
RT
"Pribehy 20. stoleti - V dnesnich Pribezich 20. stole "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 10 kHz MIN: 7 kHz % above 77 kHz: 0,0809 Acquired: 2022/08/20 4:06:00 Total samples: 18552 Equivalent time: 0:15:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 0,7 dBr MIN: -14,0 dBr AVE: -2,09 dBr % above 0,2 dBr: 6,5 Last value: 0,2 dBr (2022/08/20 4:06:00) 03:52 03:54 03:56 03:58 04:00 04:02 04:04 04:06 -15 -10 -5 0 Pm [dBr] 0 5 Signal Quality