<LOGO>
FM Transmitter Measurement Report
Created: 2021-11-21 05-53-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.00 MHz 4/5, 28 dBuV BLANIK
Pilot RDS Phase Difference
6.7 kHz 2.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
14 kHz 46 kHz 10658 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,8 dBr -0,76 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" BLANIK " 233C 10 (Pop M) 1 0 1 5 5:53, 21.11.2021
RT
"POLICE - Every Breath You Take "
AF EON
87.8, 88.4, 91.6, 93.9, 95.0, 98.0, 100.2, 100.6, 103.4, 104.7, 104.8, 104.9, 106.5, 107.4 MHz -
FM Scope Max at: 46 kHz MIN: 14 kHz % above 77 kHz: 0,0000 Acquired: 2021/11/21 5:53:09 Total samples: 10658 Equivalent time: 0:08:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,4 dBr MIN: -1,8 dBr AVE: -0,76 dBr % above 0,2 dBr: 0,0 Last value: -0,5 dBr (2021/11/21 5:53:09) 05:40 05:42 05:44 05:46 05:48 05:50 05:52 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality