<LOGO>
FM Transmitter Measurement Report
Created: 2022-07-18 11-35-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 33 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 51 kHz 18475 0,0541
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,5 dBr -0,14 dBr 0,5 dBr 6,9
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:35, 18.07.2022
RT
"Interview Plus - Jan Trnka. Moderuje Jan Bumba. "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 51 kHz MIN: 7 kHz % above 77 kHz: 0,0541 Acquired: 2022/07/18 11:35:09 Total samples: 18475 Equivalent time: 0:15:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,5 dBr MIN: -1,5 dBr AVE: -0,14 dBr % above 0,2 dBr: 6,9 Last value: -1,5 dBr (2022/07/18 11:35:08) 11:22 11:24 11:26 11:28 11:30 11:32 11:34 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality