<LOGO>
FM Transmitter Measurement Report
Created: 2022-06-09 11-08-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 41 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 46 kHz 18312 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,71 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:06, 9.06.2022
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 46 kHz MIN: 7 kHz % above 77 kHz: 0,0000 Acquired: 2022/06/09 11:08:02 Total samples: 18312 Equivalent time: 0:15:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,2 dBr MIN: -1,4 dBr AVE: -0,71 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2022/06/09 11:08:02) 10:54 10:56 10:58 11:00 11:02 11:04 11:06 11:08 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality