<LOGO>
FM Transmitter Measurement Report
Created: 2022-06-06 11-52-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 42 kHz 10532 1,5856
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -1,65 dBr -1,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:51, 6.06.2022
RT
"Interview Plus - Michal Bauer z akademickeho pracoviste CERGE..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 42 kHz MIN: 6 kHz % above 77 kHz: 1,5856 Acquired: 2022/06/06 11:52:27 Total samples: 10532 Equivalent time: 0:08:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: -1,3 dBr MIN: -2,1 dBr AVE: -1,65 dBr % above 0,2 dBr: 0,0 Last value: -1,7 dBr (2022/06/06 11:52:26) 11:38 11:40 11:42 11:44 11:46 11:48 11:50 11:52 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality