<LOGO>
FM Transmitter Measurement Report
Created: 2022-05-09 11-36-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 35 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 52 kHz 18270 0,0821
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -0,85 dBr 0,3 dBr 0,8
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:35, 9.05.2022
RT
"Interview Plus - Jana Karasova a Jaromir Marek, rozhlasovi zp..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 52 kHz MIN: 9 kHz % above 77 kHz: 0,0821 Acquired: 2022/05/09 11:36:36 Total samples: 18270 Equivalent time: 0:15:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,3 dBr MIN: -1,6 dBr AVE: -0,85 dBr % above 0,2 dBr: 0,8 Last value: -1,1 dBr (2022/05/09 11:36:36) 11:22 11:24 11:26 11:28 11:30 11:32 11:34 11:36 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality