<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-05 04-06-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 4/5, 34 dBuV R-CB
Pilot RDS Phase Difference
6.5 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 17 kHz 1159 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -1,05 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-CB " 250D 9 (Varied) 1 0 0 0 4:05, 5.05.2024
RT
"Zpravy z regionu - r "
AF EON
88.2, 103.9, 106.4 MHz -
FM Scope Max at: 17 kHz MIN: 13 kHz % above 77 kHz: 0,0000 Acquired: 2024/05/05 4:06:03 Total samples: 1159 Equivalent time: 0:00:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60 80
FM Scope MAX: -0,1 dBr MIN: -1,9 dBr AVE: -1,05 dBr % above 0,2 dBr: 0,0 Last value: -0,2 dBr (2024/05/05 4:06:03) 03:52 03:54 03:56 03:58 04:00 04:02 04:04 04:06 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality